Contents of the manual for LEDmsg Protocol Simulator(called “DABIT simulator”) is as follows:
Attachment
A-1. Communication Setting : RS-232
A-2. Communication Setting : RS-485
A-3. Communication Setting : TCP server
A-4. Communication Setting : TCP client
A-5. Communication Setting : UDP
A-6. How to set Screen Size
A-7. How to set LED Display Signal Type
A-8. How to set Controller System Font
A-9. How to set Board Function
A-10. How to do Firmware Upgrade
References
R-1. LEDmsg protocol document(html, pdf)
R-2. LEDmsg Protocol Simulator(software, manual in pdf )
R-3. DabitChe Editing Program(software, manual in pdf)
1. Introduction
LEDmsg protocol simulator is to set the configuration of the LMD controller and simulate messages of “LEDmsg Protocol”.
The best way to easily understand the LMD Protocol and apply it to the customer’s system is to purchase a simple LED Message Display Kit and demonstrate it as follows.
- To set up the communication(RS232/485, Ethernet)
- To set up the controller
- To execute the simulation of the LEDmsg protocol
2. Preparation
- Connect your PC to the LMD signboard with RS232 or Ethernet cable, and supply the power(DC5V).
- After downloading the LEDmsg Protocol simulator to your PC(Window only), double-click DABITsimulator.exe to run it.
- Click “Special Function > Communication Method” to open the “Communication setting” window and set the communication (RS232 or Ethernet…) by referring to “A-1, A-2, A-3, A-4, A-5”.
- In “Special Function” section, proceed the below settings(as for LMD-Demo-Kit):
Now you are ready to simulate the messages and special commands of “LEDmsg Protocol”.
3. Message Simulation
Here, you can enter various Real-time message and Page message packets of LEDmsg Protocol and preview them or send them directly to the LED sign board to see how it works.
First, try to simulate the basic sample messages. Then, develop the message protocol matching to your LED message sign.
- Click “ASCII Message” tab.
- Enter the message protocol in a text input box.
- Click “Save”.
- Click “Preview”.
Then, a preview window appears, showing the message display image. Preview may differ from the actual display image on the LED signboard.
To make the preview disappear, click the Preview button again. - Click “Send”.
Then, the message is displayed on the LED display board, and the actual transmitted/received protocol packets appear in the log window.
When you click “Reset Messages“, the text input boxes are reset.
“Set Message Properties” is only used under our technical support.
4. Settings and Special Commands
Here, you can set the “communication method”, “program user option”, “controller configuration”, and execute “special commands” of LEDmsg Protocol. For more details, refer to the linked page or document.
A. Setting: Communication Method
Click the button and set the communication method between the simulator(window PC) and the sign controller for your requirement.
– RS232: see “A-1”
– RS485: see “A-2”
– Ethernet: see “A-3, A-4, A-5”
B. Setting: Program User Option
– Type of Protocol: Select “ASCII Message” only.
– Language: Select “English” for non-Korean users.
C. Setting: Controller Configuration
ⓐScreen Setting: is to set the screen size, color and LED module array. For details, refer to “A-6”.
ⓑSet Page Messages: is to allocate the total page memories or reset the pages. For details, refer to “LEDmsg Protocol, Chapter 7-L/M”.
ⓓSet Brightness: is to set the brightness of LED screen. The default is 100%. For details, refer to “LEDmsg Protocol, Chapter 7-J”.
ⓓReal time Message(effect option): is only for special application.
Do not change it.
ⓔFont Transfer: is to send the system font files. ☞ Refer to “A-8”
ⓕLED Signal Type: is to set the signal type of the LED module which is different from LED chip, scan rate, manufacturer, etc.
☞ Refer to “A-7”
ⓖBoard Functions: is to set the port functions, communication speed, etc of the LMD controller. ☞ Refer to “A-9”
ⓗFirmware Upgrade: is to read the firmware version information and upgrade it under our technical support. ☞ Refer to “A-10”
D. Special Commands Simulations
For this commands, refer to “LEDmsg Protocol document, Chapter 7”.
①Turn On/Off Screen: is to turn the screen ON/OFF.
②Read Time from Controller: is to read the controller time and display them on the black display box above.
When the power is reset, the time is reset to “2070-01-01 00:00:00”.
③Update Time to Controller : is to update the controller time to the current time of your PC..
④Factory Reset: is to reset the all message and file data of the controller. But the fonts and setting parameters are maintained
⑤Send Relay Output Signal: is to send ON/OFF signals to relays which can control the power for electric buzzer, lamp, devices.
☞ In this application, refer to “How to use Relays”
⑥Select Background: is to call the background image file number to display it on LED screen. ☞ Refer to “DabitChe manual, Chapter 4 & A-6”
⑦Fill Screen Color: is to fill the screen with the selected color.
In the “Communication log” window, you can see all the transmitted/received protocol data which you can apply to your messaging program.
If you want to delete all the log data, click the trash can icon on the right.
If you click “Help”, you can refer to the Korean user manual of DABIT Simulator only.
A-1. Communication Setting : RS-232
Here describe how to connect your PC running DABIT protocol simulator to the LMD controller via RS232 communication.
On the simulator, click “Special Function > Communication Method” to open the “Communication Setting” window and proceed as follows.
- Connect the LMD controller(“J2” port) and PC with a USB to RS232 converter cable.
- For RS232 communication port location, refer to LMD controller specification.
- You can use the common USB to RS232 converter having “TX, RX, GND” terminal.
The cable connector is provided free of charge upon request when ordering the product. - UART(TTL) communication : To use UART communication with embedded controllers(Raspberry Pi, ESP32, etc.), connect the connection cable to the “TTL port (J2)” of the controller and proceed the same as follows.
- Select “Serial” and proceed to set as follows.
- Set “COM Port“(Ex. COM3).
- If you click “Device Manager”, you can check the RS232 communication port number connected to the PC. If the port does not appear, you must install the driver for the corresponding RS232 communication converter.
- Set “Baud rate“. The default is “115200bps”.
- If you click “Baudrate Search”, the communication speed of the currently connected “COM port” is found.
- To change the baud rate, please refer to “A-9”.
- Click “Open Port” and confirm the message below in the log window.
>>”COM3 : 115,200bps, 8, 1, N – ComPort Open [OK]” - Click “Connect DABIT” and confirm the message below in the log window“.
>>“DIBD Connecting… [OK] 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03”
>>“Receive : 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03” - Click “Close” to close the “Communication setting” window.
A-2. Communication Setting : RS-485
Here describe how to connect your PC running DABIT protocol simulator to the LMD controller via RS485 communication.
On the simulator, click “Special Function > Communication Method” to open the “Communication Setting” window and proceed as follows.
- Insert the RS485 communication gender into the “BH1” port of the controller, and connect RS485 cable to the terminal “A, B”.
For more details, see “How to use RS485 converter”. - Select “Serial > RS-485“ and proceed to set as follows.
- Set “COM Port”(Ex. COM3).
If you click “Device Manager”, you can check the RS232 communication port number connected to the PC. If the port does not appear, you must install the driver for the corresponding RS232 communication converter. - Set “Baud rate”. The default is “115200bps”.
If you click “Baud rate Search”, the communication speed of the currently connected COM port is found.
To change the baud rate, please refer to “A-9”. - Set the address. The default is “00”.
Up to 31 addresses can be set using dip switches on the RS485 communication gender. For details, refer to “How to use RS485 converter”.
- Set “COM Port”(Ex. COM3).
- Click “Open Port” and confirm the message below in the log window
>>”COM3 : 115,200bps, 8, 1, N – ComPort Open [OK]” - Click “Connect DABIT” and confirm the message below in the log window“.
>>“DIBD Connecting… [OK] 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03
>>“Receive : 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03” - Click “Close” to close the “Communication setting” window.
A-3. Communication Setting : TCP server
Here describe how to set up communication by directly connecting your laptop(TCP client) to the LED signboard(TCP server) with a RJ45 Ethernet cable.
The default of the LMD controller is “IP: 192.168.0.202(or 201), Port: 5000, Server mode” and can be checked and changed as follows.
Step 1: Connect the laptop and the device(LED controller) with an RJ45 cable and supply the power to the device.
line break
Step 2: Manually set the laptop’s IP as follows (Windows 11) [Note 1]
- Go to “Control Panel > Network and Internet > Network and Sharing Center > Change adapter settings“ to open the “Network Connections” window.
- Right-click on “Ethernet” and click “Properties > Internet Protocol Version 4 (TCP/IPv4) > Properties”.
Then, the “Properties” setting window appears. - Select “Use the following IP address” and set the IP of the laptop as below example.
– IP address: 192.168.0.200
– Subnet mask: 255.255.255.0
– Gateway: 192.168.0.1 - If there are two or more network adapters connected to the laptop(or PC), perform additional steps as follows.[Note 2]
- Click “Advanced…” to open “Advanced TCP/IP Settings” window.
- After unchecking “Automatic metric”, enter “Interface metric” as the highest priority, “1”.
- Click “OK” to close the setting window.
[Note 1] If the laptop and the LED sign are connected through a router on the same network, steps “2.① ~ 2.④” are omitted.
[Note 2] The DABIT Net program searches for controllers through UDP broadcast, and if there are more than two network adapters connected to the laptop, problems with UDP communication priority may occur.
Therefore, change the Interface metric of the adapter connected to the LED signboard to the highest priority “1” and use the DABIT Net program.
After using the program, don’t forget to restore “Automatic metric” to its original state.
Step 3: On the simulator, click “Special Function > Communication Method” to open the “Communication Setting” window and proceed as follows.
- Set your laptop to “Client TCP/IP” mode.
- Click [DABITNet] to open “DABIT Net Setting” window.
☞ If the DABIT net program does not run, go to “Windows Security”, disable “Virus & threat protection” or “Firewall & network protection”, and then restart the program. - Click [Search]. Then, the list of all devices connected to the same network appears in the “Board List”.
- Click the MAC address in the list. Then, the IP information of the device appears in the right area under “Network” tab. The default is as follows.
– Local IP : 192.168.0.201(or 202) – Port : 5000 – Gateway : 192.168.0.1 – Operation Mode : Server - If you want to change the IP information of the device(in Server mode) to suit your network environment, proceed as follows.
- Click the device MAC address.
- Among the IP information on the right section, change the desired items (IP, Port, Gateway, etc.) and click [Set].
Then, the changed information is updated on the device (takes about 5 seconds). - Click [Search] again. Then, the changed information is applied and displayed.
- Click [Exit] to close “DABIT Net Setting” window.
- Enter IP Address and Port number in “Client TCP/IP” section. (e.g. 192.168.0.202, #5000)
- Click [Connected]. If the message below appears in the “Log” window, the server port is normally opened.
>> “IP:192.168.0.202, PORT:5000 Open [OK]” - Click [Connect DABIT]. If the message below appears in the “Log” window, the TCP connection is OK.
>>“DIBD Connecting… [OK] 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03”
>>“Receive : 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03” - Click [Close] to close “Communication Setting” window.
[TIP 1] If you click [Search] and the device does not appear, check the following one by one.
ⓐ Among the two LEDs on the left and right of the RJ45 connector, check whether one is lit and one is blinking(in communicating).
ⓑ Check “Step 2” above.
ⓒ In DABIT Net Setting window, go to “COMM > UDP” and make sure that “Search Type” is set to “Ethernet Devices“
ⓓ Reset the device’s power.
A-4. Communication Setting : TCP client
Here, we will explain how to set up communication by directly connecting your laptop(TCP server) and the LED signboard(TCP client) with a RJ45 Ethernet cable.
Step 1: Execute “Step 1,2” of “A-3” above.
Step 2: Run the simulator and click “Special Function > Communication Method” to open the “Communication Setting” window and proceed as follows.
- Set your laptop to “Server TCP/IP” mode.
- Click [DABITNet] to open “DABIT Net Setting” window.
☞ If the DABIT net program does not run, go to “Windows Security”, disable “Virus & threat protection” or “Firewall & network protection”, and then restart the program. - Click [Search]. Then, the list of all devices connected to the same network appears in the “Board List”.
- Click the MAC address in the list. Then, the IP information of the device appears in the right area under “Network” tab.
The default is “Local IP: 192.168.0.201(or 202), Port: 5000, Gateway: 192.168.0.1, Device Operation Mode: Server “ - Change the Operation Mode(Controller) to “Client”. Then, “Server IP, Port” input boxes are enabled.
Depending on your network environment, set the Local IP, Port, and Gateway of the Client (controller) and the IP & Port of the Server (laptop) .
Here, as an example, enter only the IP and port of the server laptop as “192.168.0.200, Port “5000”.
The server IP can also be entered in the form of a domain(e.g. www.LEDmsg.com).
You can check the laptop’s IP by opening the “CMD” window and typing/entering “ipconfig.” >>How to find your IP address - Click [Set]. After about 5 seconds, click [Search] again.
Then, you can confirm that the changed information has been applied. - Click [Exit] to close “DABIT Net Setting” window.
- Enter the Port number. (e.g. #5000)
- Click [Connected]. If the message below appears in the “Log” window, the server port is normally opened.
>> “IP:192.168.0.202, PORT:5000 Open [OK]” - Click [Connect DABIT]. If the message below appears in the “Log” window, the TCP connection is OK.
>>“DIBD Connecting… [OK] 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03”
>>“Receive : 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03” - Click [Close] to close “Communication Setting” window.
A-5. Communication Setting : UDP
LMD-C2/C3 controllers can use both TCP and UDP communications.
Generally, TCP communication is used, but UDP communication can also be used when there is a problem with TCP communication.
Here, we describe how to communicate with the DABIT Protocol simulator using UDP.
Step 1: Execute “Step 1,2” of “Attachment 3-1”.
Step 2: Run the simulator and click “Special Function > Communication Method” to open the “Communication Setting” window and proceed as follows.
- Select “UDP” mode.
And enter the IP address and Port number.
– IP address : 192.168.0.202 (You can change it as “A-3 > Step 3 > 5” above).
– UDP port is fixed to “5108”. - Click [Connected]. If the message below appears in the “Log” window, the server port is normally opened.
>> “UDP IP:192.168.0.202, Remote PORT:5108, Local PORT:5109 UDP Open [OK]” - Click [Connect DABIT]. If the message below appears in the “Log” window, the TCP connection is OK.
>>“DIBD Connecting… [OK] 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03”
>>“Receive : 10 02 00 00 0B 6A 30 31 32 33 34 35 36 37 38 39 10 03” - Click [Close] to close “Communication Setting” window.
A-6. How to set Screen Size
The LMD controller must set the screen size after connecting the HUB75 dot matrix LED module.
Run “DABIT Protocol Simulator” and set it at “Special Function > Screen Setting” section.
“Bit Per Pixel” is fixed to “3BPP (8 Color)”.
Module Array is generally set to “Horizontal (default)”, and when using a double-sided screen, it is set to “Horizontal Twin” according to our technical support.
In this regard, refer to the following features of HUB75 dot matrix LED module.
- LED modulel is manufactured in various sizes in multiples of “16×16“ pixel.
- The pitch between pixels varies from “2,3,4,5,6,8,10mm”.
- Those with a pitch of 4mm or less are mainly used indoors with a viewing distance of 12m or less and a brightness of 1200nit or less.
- Those with a pitch of 6mm or more are mainly used for outdoor applications with a viewing distance of 10 ~ 30m and a brightness of 4000nit or more.
- The display color supports RGB full color.
- Each module has two data connectors(16-Pin IDC, IN/OUT) and one power connector(4-pin, DC 5V).
Here are the examples of connecting and setting the LMD controller and LED modules with 16-pin data cables.
A-7. How to set LED Display Signal Type
To use the LMD controller, you must select the Display Signal Type that matches the LED module.
Display signal type is a method of sending a display signal from the LMD controller to the LED module and varies for each LED module.
When the signal type is set correctly, straight LED bars are displayed in “up and down, left and right, and diagonal” directions as follows.
However, if the signal type is incorrect, the shape of the LED bars is distorted and the characters are displayed brokenly.
The LMD controller is programmed with various signal types to meet various kinds of HUB75 RGB 16×16 matrix LED modules.
However, many of the HUB75 LED modules in the market may not yet be compatible with our LMD controllers.
For information about Display Signal type of LMD LED modules, please see >>here<<.
If you want to check whether the HUB75 LED module you want to use is compatible with the LMD controller, follow the steps below:
- Click “Special Functions > LED Signal Type” to open “LED Signal Setting” window.
- Select the right “Signal Type”.
The default setting for LMD controller is “16D-P16D1S11”.
“16D…” is for “HUB75 P3, P4, P5” LED modules with 1/16 scan.
“08D…” is for “HUB75 P4, P5, P6” LED modules with 1/8 scan.
“04D…” is for “HUB75-P8, P10” LED modules with 1/4 scan.
“32D/02D/01D…” can be used only by our technical support.
Signal types shown in pink are not for HUB75 LEDs.
Typically, the scan rate is “1/32, 1/16, 1/8” for indoor module and “1/8, 1/4” for outdoor module. - Select “Color Order”. This is usually set to RGB.
- Select “Scan Order”.
In general, the setting is disabled and no need to select.
But if it is enabled when you select specific signal type(e.g. “08D-P64D1S21”), you must select the right “Scan order”. - Click “Send” and check whether the display image of the LED bars or text is correct as the picture above.
A-8. How to set Controller System Font
The LMD controller displays various characters using the following three types of system fonts pre-stored in Flash ROM.
Various font files are stored in the “Simulator > Sys > Font” folder, so the user can select and change it if necessary.
Background images (text, graphics, animation) edited and transmitted using the Dabitche program are displayed regardless of these system font.
Here’s how to change the font file:
- Run the DABIT Protocol Simulator.
- Click “Special Functions > Font Transfer” to open the “Font Setting” window on the right.
- Check “Font Group 0”.
- Select the desired font file for each type.
- Click “Send”.
Then, the font file of the corresponding type is stored in the flash memory of the controller.
Customers who require the advanced information below, please contact us.
- How to use European extended fonts
- How to display wide (16×16) ASCII characters
- How to edit font files
- How to transmit several font groups and display them individually
A-9. How to set Board Function
You can change the function and speed of the ports on the LMD controller.
Port | BH1 | J2 | J3 | J4 |
Default value | TTL/RS485 | RS232 115200bps | TTL 115200bps | Relay Signal Output |
The following are examples of port function changes from the above default.
Case 1: How to change the RS232 communication speed of “J2” port to 9600bps
① Click “Special Functions > Board Functions” to open “Board Functions” setting window.
② Select “Read” in “2.Sub Command” and click “Send”. Then, you can see the current setting value of each port.
③ Select “2.Sub Command” to “Set”.
④ Change “6.J2(RS232) Baudrate” to “9600”. Then, click “Send”.
⑤ Click “Communication Method” to open “Communication Setting’ window.
⑥ You can start communication by checking “Serial”, setting the COM port, and changing the Baud rate to “9600bps”.
In this way, the communication speed of “J3 (TTL), BH1 (RS485)” can also be changed.
Case 2: How to change “J4” port from “Relay out” to “CdS sensor” use mode
A. Proceed “Case 1-①②③” as the same as the above.
B. Change “5.J4 Function” from “Relay out” to “CDS”. Then, click “Send”.
C. Select “Read” in “2.Sub Command” and click “Send”.
Then, you see that the function of “J4” port has been changed to “CDS”.
Now, you can automatically adjust the brightness of the LED screen by connecting the cable(2 pin) of the CdS cell to the J4 port of the LMD controller. For further details, please refer to “How to use CdS sensor“.
Case 3: . How to change “BH1” port ” to “8Pin Input(HEX)” use mode
A. Proceed “Case 1-①②③” as the same as the above.
B. Change “8.BH1 Function” from “TTL/RS485(default)” to “8Pin Input(HEX)”. Then, click “Send”.
C. Select “Read” in “2.Sub Command” and click “Send”.
Then, you see that the function of “BH1” port has been changed to “8Pin Input(HEX)”.
Now, by connecting the cable (10 pin) of the LMD Switch IO board to the BH1 port of the LMD controller, you can directly receive signals from PLC/Switches, etc. and display the corresponding image file of BG playist. For further details, please refer to How to use Switch IO Board.
A-10. How to do Firmware Upgrade
Firmware upgrades for LMD controllers should only be performed under our technical support in the following cases:
- When you need to change to the latest version of firmware
- When you need to change the firmware to reflect the your special requirements
Even if you change the firmware, the existing setting information is maintained.
The firmware upgrade method is as follows:
Step 1: Save the firmware file of the form below provided by us in the “DABIT Simulator > Firmware” folder.
>> DB502S_08C_02R016C_V9.16.bin
Step 2: Run “DABIT Simulator” and proceed as follows:
① Click “Special Functions > Firmware Upgrade” to open “Firmware Upgrade” window.
② Click “Read” to see the current firmware information.
③ Click “Open”. When the “search box” appears, select the firmware you want to upgrade.
④ Click “Send” to upgrade the LMD controller with the new firmware within a minute.
⑤ Click “Close” to close the window.
If you have any question on the LEDmsg protocol simulator manual, feel free to contact “LEDmsg01@gmail.com”.